Document Details
Name of Department/Committee : CHD 30
Document Number : CHD 30 ( 23538)
Document Title [English] : MEASUREMENT AND PREDICTION OF THE AMBIENT DOSE EQUIVALENT FROM PATIENTS RECEIVING IODINE 131 ADMINISTRATION AFTER THYROID ABLATION PART 1: DURING THE HOSPITALIZATION
Document Title [Hindi] : थायरॉइड एब्लेशन उपचार के बाद आयोडीन 131 एडमिनिस्ट्रेशन प्राप्त करने वाले रोगियों से परिवेश खुराक समतुल्य का माप और पूर्वानुमान — भाग 1: अस्पताल में भर्ती होने के दौरान
Document Type : New
Language : English
Priority : 2
ICS Code : 13.280
Date of Project Approval : 18-08-2023
Standards to be Superseded :


Classification Details
Group : Chemicals, Plastics and their Products including packaging and Environment
Sub Group : Chemicals
Sub Sub Group : Radioactive Residue Test Methods
Aspects : Methods of tests
Risk : Low
Certification : Not Certifiable
Short Commom Man's Title :
ITCHS Code :
Ministry :
  • Department of Atomic Energy
Sustainable development Goals :
  • INDUSTRY, INNOVATION AND INFRASTRUCTURE
Degree of Equivalence : Identical under dual numbering
Identical/Equivalent Standards : ISO 18310-1 : 2017
Organization Type: ISO

Division Council Chairperson Approval Details
Request Date: 02-01-2024
Status of Chairperson Approval: Division Council Chairperson approval uploaded by member secretary  (Click to View)
Division Council Chairperson : Sourav Pal
Attachment :  View File 1
 View File 2
Sectional Committee Chairman Approval :
 View


::Cross Referenced Indian Standard::
Sl. No. Is No & Year IS Title
1 IS 17986 : Part 1: 2023 Radiological Protection -X and Gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy- Part 1 : Radiation characteristics and production methods
2 IS 17986 : Part 3: 2022 Radiological protection - X and Gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy- Part 3 : Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence.
3 IS 18070 : 2023 Reference radiation fields for radiation protection - Definitions and fundamental concepts
4 IS/ISO/IEC GUIDE 99 : 2007 International vocabulary of metrology � Basic and general concepts and associated terms (VIM)

Sl.No. Synosis Points
1 This document specifies suitable methods for the measurement of ambient dose equivalent rate at a distance from the patient treated with radioiodine to ablate the thyroid. For this purpose, direct measurement of the ambient dose equivalent rate due to the inpatients using an ionization chamber (or other suitable devices) may be employed. This document addresses the measurement methods, the calibration of ionization chamber and the uncertainty estimation for the measurement of the ambient dose equivalent rate of the patient treated with radioiodine to ablate the thyroid using the ionization chamber

Timeline Details


S.No. P-Draft
Completion Date
WC-Draft
Completion Date
Final-Draft
Completion Date
Project
Completion Date(Gazette)
Entered By Entered On
1 06-09-2023 06-01-2024 06-02-2024 06-06-2024 Mr. PUSHPENDRA KUMAR 06-09-2023