Document Details
Name of Department/Committee : LITD 09
Document Number : LITD 09 ( 24955)
Document Title [English] : Electromagnetic Compatibility EMC Part 4: Testing and Measurement Techniques Section 6: Immunity to Conducted Disturbances Induced by Radio-Frequency Fields First Revision
Document Title [Hindi] : विद्युत चुंबकीय संगतता (ई एम सी) – भाग 4: परीक्षण एवं मापन तकनीकें – अनुभाग 6: रेडियो आवर्ती क्षेत्रों द्वारा प्रेरित चालित विक्षोभों से प्रतिरक्षा (पहला पुनरीक्षण)
Document Type : Revision
Language : English
Priority : 3
ICS Code : ICS 33.100.01
Date of Project Approval : 02-11-2023
Standards to be Revised :
Sl.No. Is No & Year
1 IS 14700 : Part 4 : Sec 6: 2016
Standards to be Superseded :


Classification Details
Group : Electronic and Telecom equipments, components and devices
Sub Group : Electronic equipments and systems
Sub Sub Group : Electromagnetic Compatibility and Electromagnetic Interference
Aspects : Methods of tests
Risk : None
Certification : None
Short Commom Man's Title :
ITCHS Code :
Ministry :
  • Ministry of Electronics and Information Technology
  • Ministry of Communication - Department of Telecommunications
Sustainable development Goals :
Degree of Equivalence : Identical under dual numbering
Identical/Equivalent Standards : IEC 61000-4-6:2023
Organization Type: IEC

Sl.No. Synosis Points
1 IEC 61000-4-6: 2023 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation are intended to be used in the frequency range up to 80 MHz.
2 Equipment not having at least one conducting wire or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this document. NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects. The object of this document is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method in this document describes a consistent method to assess the
3 NOTE 3 As described in IEC Guide 107, this document is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. This fifth edition cancels and replaces the fourth edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) selection of injection devices revised; b) need of AE impedance check for clamp injection removed and Annex H deleted; c) saturation check revised; d) new Annex H on testing with multiple signals; e) level-setting only with feedback loop.

Timeline Details


S.No. P-Draft
Completion Date
WC-Draft
Completion Date
Final-Draft
Completion Date
Project
Completion Date(Gazette)
Entered By Entered On
1 23-02-2024 23-07-2024 08-10-2024 23-02-2025 SHRI BIPIN JAMBHOLKAR 23-02-2024
Stages
Sl.
No.
Stage Date of Occurence Remarks Circulated to Files
1 Generation of Document Number 02-11-2023 -------
2 P-Draft Waived 26-02-2024 -------
3 WC Draft 26-02-2024 Duration : 60 Days
Submitted for HOD approval
Remarks : The committee decided to issue Wide Circulation for a period of 2 months All committee members are requested to give their Inputs Comments on or berfor 26 April 2024
-------
4 WC Draft 27-02-2024 WC approved by HOD
LITDC   -------