Document Details
Name of Department/Committee : LITD 09
Document Number : LITD 09 ( 25163)
Document Title [English] : Assessment of Power Density of Human Exposure to Radio Frequency Fields from Wireless Devices in Close Proximity to the Head and Body Frequency Range of 6 Ghz to 300 Ghz Part 1: Measurement Procedure
Document Title [Hindi] : मस्तिष्क और शरीर के निकट वायरलेस उपकरणों से रेडियो फ्रीक्वेंसी क्षेत्रों के संपर्क में आने वाले मानव के शक्ति घनत्व का आकलन (फ़्रीक्वेंसी रेंज 6 गीगाहर्ट्ज़ से 300 गीगाहर्ट्ज़) - भाग 1: मापन प्रक्रिया
Document Type : New
Language : English
Priority : 3
ICS Code : ICS 17.220.20
Date of Project Approval : 01-03-2024
Standards to be Superseded :


Classification Details
Group : Electronic and Telecom equipments, components and devices
Sub Group : Electronic equipments and systems
Sub Sub Group : Electromagnetic Compatibility and Electromagnetic Interference
Aspects : Methods of tests
Risk : None
Certification : Not Certifiable
Short Commom Man's Title :
ITCHS Code :
Ministry :
  • Ministry of Electronics and Information Technology
  • Ministry of Communications - Department of Telecommunications (DOT)
Sustainable development Goals :
  • SUSTAINABLE CITIES AND COMMUNITIES
  • GOOD HEALTH AND WELL BEING
Degree of Equivalence : Identical under single numbering
Identical/Equivalent Standards : IEC/IEEE 63195-1:2022
Organization Type: IEEE

Sl.No. Synosis Points
1 This document specifies protocols and test procedures for repeatable and reproducible measurements of power density (PD) that provide conservative estimates of exposure incident to a human head or body due to radio-frequency (RF) electromagnetic field (EMF) transmitting communication devices, with a specified measurement uncertainty. These protocols and procedures apply for exposure evaluations of a significant majority of the population during the use of hand-held and body-worn RF transmitting communication devices. The methods apply for devices that can feature single or multiple transmitters or antennas, and can be operated with their radiating structure(s) at distances up to 200 mm from a human head or body.
2 The methods of this document can be used to determine conformity with applicable maximum PD requirements of different types of RF transmitting communication devices being used in close proximity to the head and body, including if combined with other RF transmitting or nontransmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range of these protocols and procedures is from 6 GHz to 300 GHz. The RF transmitting communication device categories covered in this document include but are not limited to mobile telephones, radio transmitters in personal computers, desktop and laptop devices, and multi-band and multi-antenna devices.
3 NOTE 1 System validation tests are specified in Annex B for 10 GHz, 30 GHz, 60 GHz, and 90 GHz to cover the frequency range from 6 GHz to 110 GHz. Additional validation antennas to cover the frequency range up to 300 GHz will be developed in a future revision of this document. Further discussion on rationales is given in Annex I. NOTE 2 The protocols and test procedures in this document can be adapted to evaluate exposure also due to noncommunication types of devices operating in close proximity to the head and body, but these devices are not in the scope of this document. NOTE 3 For the assessment of the combined exposure from simultaneous transmitters operating on frequencies below 6 GHz, the relevant standards for SAR measurements are IEC/IEEE 62209-1528:2020 and IEC/IEEE 62209-3:2019 [1].
4 NOTE 4 Between 6 GHz and 10 GHz, the scopes of this document and IEC/IEEE 62209-1528:2020 overlap. According to ICNIRP [2] guidelines and IEEE ICES C95.1 [3] standard, power density is the conformity metric in this frequency range. SAR can be used as conformity metric if local regulatory requirements allow it. (e.g. in case where a single transmit band includes test channels at both below and above 6 GHz). The procedures of this document do not apply for EMF measurements of devices or objects intended to be implanted in the body.

Timeline Details


S.No. P-Draft
Completion Date
WC-Draft
Completion Date
Final-Draft
Completion Date
Project
Completion Date(Gazette)
Entered By Entered On
1 03-04-2024 03-09-2024 18-11-2024 02-04-2025 SHRI BIPIN JAMBHOLKAR 03-04-2024
Stages
Sl.
No.
Stage Date of Occurence Remarks Circulated to Files
1 Generation of Document Number 01-03-2024 -------
2 P-Draft Waived 03-04-2024 -------
3 WC Draft 24-04-2024 Duration : 60 Days
Submitted for HOD approval
-------
4 WC Draft 24-04-2024 WC approved by HOD
LITDC   -------