Name of Department/Committee : | PGD 15 | ||||
---|---|---|---|---|---|
Document Number : | PGD 15 ( 25333) | ||||
Document Title [English] : | Ergonomics 3-D scanning methodologies for internationally compatible anthropometric databases : Part 2 Evaluation protocol of surface shape and repeatability of relative landmark positions | ||||
Document Title [Hindi] : | एर्गोनॉमिक्स –– अंतरराष्ट्रीय स्तर पर संगत एंथ्रोपोमेट्रिक डेटाबेस के लिए 3-डी स्कैनिंग कार्यप्रणाली भाग 2 सतह के आकार का मूल्यांकन प्रोटोकॉल और सापेक्ष लैंडमार्क स्थितियों की पुनरावृत्ति | ||||
Document Type : | Revision | ||||
Language : | English | ||||
Priority : | 3 | ||||
ICS Code : | 13.180 | ||||
Date of Project Approval : | 17-01-2024 | ||||
Standards to be Revised : |
|
||||
Standards to be Superseded : |
|
Classification Details |
|
Group : | Ergonomics and Anthropometry |
Sub Group : | Anthropometry and Biomechanics |
Sub Sub Group : | Anthropometry and Biomechanics |
Aspects : | Methods of tests |
Risk : | None |
Certification : | None |
Short Commom Man's Title : | |
ITCHS Code : | |
Ministry : |
|
Sustainable development Goals : |
|
Degree of Equivalence : | Identical under dual numbering |
Identical/Equivalent Standards : | ISO 20685-2:2023 |
Organization Type: | ISO |
Sl.No. | Synosis Points | |
1 | This document establishes protocols for testing of 3-D surface-scanning systems in the acquisition of human body shape data and measurements. It does not apply to instruments that measure the motion of individual landmarks. | |
2 | This document covers whole-body scanners and also applies to body-segment scanners (e.g., head, hand, foot scanners) that measure the human body in a single view. It addresses issues such as errors introduced by human operators and movement artifacts in rotated participant scans. It focuses on landmark positions determined by anthropometrists rather than software-generated ones. Scanner and human performance affect the quality of body surface shape and landmark positions. The document evaluates scanner systems using artifacts instead of human participants and emphasizes the need for accuracy comparable to traditional instruments. It targets users, data consumers, and designers/manufacturers of 3-D body scanners, aiming to establish performance standards and agreements among stakeholders. |
Timeline Details |
|||||||
|
|||||||
|
|||||||
|
|||||||
Stages |
|||||
Sl. No. |
Stage | Date of Occurence | Remarks | Circulated to | Files |
1 | Generation of Document Number | 17-01-2024 | ------- | ||
2 | P-Draft Waived | 22-04-2024 | ------- | ||
3 | WC Draft | 22-04-2024 | Duration : 60 Days Submitted for HOD approval Remarks : WC draft is put up for kind consideration and approval please |
------- | |
4 | WC Draft | 23-04-2024 | WC rejected by HOD Remarks: Please correct as indicated on the hard copy. |
------- | |
5 | WC Draft | 24-04-2024 | Duration : 60 Days Submitted for HOD approval Remarks : Corrected WC draft is put up for kind consideration and approval please |
------- | |
6 | WC Draft | 24-04-2024 | WC approved by HOD |
PGDC | ------- |