Know Your Standard Standards under Mandatory Certification Group Wise Classification Ministry/Department Wise Classification
Total Standards : 116
Revised Standards
New Standards
| S.No | IS Number | IS Title | Amendment | Reaffirmation Year | Document | Action |
|---|---|---|---|---|---|---|
| 1 |
IS 10418 : 2024 (First Revision) |
Drums for Electric Cables - Specification (First Revision) | 0 | ---- | Buy | |
| 2 |
IS 10462 (Part 1) : 1983 Reviewed In : 2021 |
Fictitious calculation method for determination of dimensions of protective coverings of cables: Part 1: elastomeric and thermoplastic insulated cables | 0 | Nov, 2021 | Buy | |
| 3 |
IS 10810 (Part 0) : 1984 Reviewed In : 2021 |
Methods of test for cables Part 0 General | 0 | Nov, 2021 | Download | |
| 4 |
IS 10810 (Part 1) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 1 annealing test for wires used as conductors | 0 | Nov, 2021 | Download | |
| 5 |
IS 10810 (Part 2) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 2 tensile test for aluminium wires | 0 | Nov, 2021 | Download | |
| 6 |
IS 10810 (Part 3) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 3 wrapping test for aluminium wires | 0 | Nov, 2021 | Download | |
| 7 |
IS 10810 (Part 4) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 4 persulphate test of conductor | 0 | Nov, 2021 | Download | |
| 8 |
IS 10810 (Part 5) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 5 conductor resistance test | 0 | Nov, 2021 | Download | |
| 9 |
IS 10810 (Part 6) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 6 thickness of thermoplastic and elastomeric insulation and sheath | 0 | Nov, 2021 | Download | |
| 10 |
IS 10810 (Part 7) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 7 tensile strength and elongation at break of thermoplastic and elastomeric iNsulation and sheath | 0 | Nov, 2021 | Download | |
| 11 |
IS 10810 (Part 8) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 8 breaking strength and elongation at break for impregnated paper insulation | 0 | Nov, 2021 | Download | |
| 12 |
IS 10810 (Part 9) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 9 tear resistance for paper insulation | 0 | Nov, 2021 | Download | |
| 13 |
IS 10810 (Part 10) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 10 loss of mass test | 0 | Nov, 2021 | Download | |
| 14 |
IS 10810 (Part 11) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 11 thermal ageing in air | 0 | Nov, 2021 | Download | |
| 15 |
IS 10810 (Part 12) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 12 shrinkage test | 0 | Nov, 2021 | Download | |
| 16 |
IS 10810 (Part 13) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 13 ozone resistance test | 0 | Nov, 2021 | Download | |
| 17 |
IS 10810 (Part 14) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 14 heat shock test | 0 | Nov, 2021 | Download | |
| 18 |
IS 10810 (Part 15) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 15 hot deformation test | 0 | Nov, 2021 | Download | |
| 19 |
IS 10810 (Part 16) : 1986 Reviewed In : 2021 |
Methods of test for cables: Part 16 accelerated ageing test by oxygen pressure method | 0 | Nov, 2021 | Download | |
| 20 |
IS 10810 (Part 17) : 1986 Reviewed In : 2021 |
Methods of test for cables: Part 17 tear resistance test for heavy duty sheath | 0 | Nov, 2021 | Download | |
| 21 |
IS 10810 (Part 19) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 19 bleeding and blooming test | 0 | Nov, 2021 | Download | |
| 22 |
IS 10810 (Part 20) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 20 cold bend test | 0 | Nov, 2021 | Download | |
| 23 |
IS 10810 (Part 21) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 21 cold impact test | 0 | Nov, 2021 | Download | |
| 24 |
IS 10810 (Part 22) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 22 vicat softening point | 0 | Nov, 2021 | Download | |
| 25 |
IS 10810 (Part 23) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 23 melt - Flow index | 0 | Nov, 2021 | Download | |
| 26 |
IS 10810 (Part 24) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 24 water soluble impurities test of insulating paper | 0 | Nov, 2021 | Download | |
| 27 |
IS 10810 (Part 25) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 25 conductivity of water extract test of insulating paper | 0 | Nov, 2021 | Download | |
| 28 |
IS 10810 (Part 26) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 26 PH value of water extract test of insulating paper | 0 | Nov, 2021 | Download | |
| 29 |
IS 10810 (Part 27) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 27 ash content test of insulating paper | 0 | Nov, 2021 | Download | |
| 30 |
IS 10810 (Part 28) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 28 water absorption test (Electrical) | 0 | Nov, 2021 | Download | |
| 31 |
IS 10810 (Part 29) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 29 environmental stress cracking test | 0 | Nov, 2021 | Download | |
| 32 |
IS 10810 (Part 30) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 30 hot set test | 0 | Nov, 2021 | Download | |
| 33 |
IS 10810 (Part 31) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 31 oil resistance test | 0 | Nov, 2021 | Download | |
| 34 |
IS 10810 (Part 32) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 32 carbon content test for polyethylene | 0 | Nov, 2021 | Download | |
| 35 |
IS 10810 (Part 33) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 33 water absorption test (Gravimetric) | 2 | Nov, 2021 | Download | |
| 36 |
IS 10810 (Part 34) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 34 measurement of thickness of metallic sheath | 0 | Nov, 2021 | Download | |
| 37 |
IS 10810 (Part 35) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 35 determination of tin in lead alloy for | 0 | Nov, 2021 | Download | |
| 38 |
IS 10810 (Part 36) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 36 dimensions of armouring material | 0 | Nov, 2021 | Download | |
| 39 |
IS 10810 (Part 37) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 37 tensile strength and elongation at break of armouring materials | 0 | Nov, 2021 | Download | |
| 40 |
IS 10810 (Part 38) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 38 torsion test on galvanized steel wires for armouring | 0 | Nov, 2021 | Download | |
| 41 |
IS 10810 (Part 39) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 39 winding test on galvanizedsteel strips for armouring | 0 | Nov, 2021 | Download | |
| 42 |
IS 10810 (Part 40) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 40 uniformity of zinc coating on steel armour | 1 | Nov, 2021 | Download | |
| 43 |
IS 10810 (Part 41) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 41 mass of zinc coating on steel armour | 0 | Nov, 2021 | Download | |
| 44 |
IS 10810 (Part 42) : 1984 Reviewed In : 2021 |
Methods of test - For cables: Part 42 resistivity test of armour wires and strips and conductance test of armour (Wires strips) | 1 | Nov, 2021 | Download | |
| 45 |
IS 10810 (Part 43) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 43 insulation resistance | 0 | Nov, 2021 | Download | |
| 46 |
IS 10810 (Part 44) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 44 spark test | 0 | Nov, 2021 | Download | |
| 47 |
IS 10810 (Part 45) : 1984 Reviewed In : 2021 |
Methods of test for cables:Part 45 high voltage test | 0 | Nov, 2021 | Download | |
| 48 |
IS 10810 (Part 46) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 48 partial dischar6e test | 0 | Nov, 2021 | Download | |
| 49 |
IS 10810 (Part 47) : 1984 Reviewed In : 2020 |
Methods of test for cables: Part 47 impulse test | 1 | Mar, 2020 | Download | |
| 50 |
IS 10810 (Part 48) : 1984 Reviewed In : 2021 |
Ethods of test for cables: Part 48 dielectric power factor test | 0 | Nov, 2021 | Download | |
| 51 |
IS 10810 (Part 49) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 49 heating cycle test | 0 | Nov, 2021 | Download | |
| 52 |
IS 10810 (Part 50) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 50 bending test | 0 | Nov, 2021 | Download | |
| 53 |
IS 10810 (Part 51) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 51 dripping test | 0 | Nov, 2021 | Download | |
| 54 |
IS 10810 (Part 53) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 53 flammability test | 0 | Nov, 2021 | Download | |
| 55 |
IS 10810 (Part 54) : 1984 Reviewed In : 2021 |
Methods of test for cables: Part 54 static flexibility test | 0 | Nov, 2021 | Download | |
| 56 |
IS 10810 (Part 55) : 1986 Reviewed In : 2021 |
Methods of test for cables: Part 55 abrasion test | 0 | Nov, 2021 | Download | |
| 57 |
IS 10810 (Part 56) : 1987 Reviewed In : 2017 |
Methods of test for cables: Part 56 accelerated ageing test by air pressure method | 0 | Download | ||
| 58 |
IS 10810 (Part 57) : 1987 Reviewed In : 2025 |
Methods of test for cables apart 57 flexing test | 0 | Jul, 2025 | Download | |
| 59 |
IS 10810 (Part 58) : 1998 Reviewed In : 2019 |
Method of tests for cables:Part 58 oxygen index test | 0 | Buy | ||
| 60 |
IS 10810 (Part 59) : 1988 Reviewed In : 2020 |
Methods of test for cables Part 59 determination of the amount of halogen acid gas evolved during combustion of polymeric materials taken from cables | 1 | Mar, 2020 | Download | |
| 61 |
IS 10810 (Part 60) : 1988 Reviewed In : 2020 |
Methods of test for cables: Part 60 thermal stability of PVC insulation and sheath | 1 | Mar, 2020 | Download | |
| 62 |
IS 10810 (Part 61) : 1988 Reviewed In : 2020 |
Methods of test for cables: Part 61 flame retardant test | 1 | Mar, 2020 | Download | |
| 63 |
IS 10810 (Part 62) : 1993 Reviewed In : 2019 |
Method of tests for cables: Part 62 flame retardance test for bunched cables | 0 | Apr, 2019 | Download | |
| 64 |
IS 10810 (Part 63) : 1993 Reviewed In : 2019 |
Method of tests for cables: Part 63 measurement of smoke density of electric cables under fire conditions | 0 | Apr, 2019 | Download | |
| 65 |
IS 10810 (Part 64) : 2003 Reviewed In : 2022 |
Methods of test for cables: Part 64 measurement of temperature index | 0 | Feb, 2022 | Download | |
| 66 |
IS 10877 : 1984 Reviewed In : 2021 |
Dimensions for moulds for cast resin based indoor terminations for cables for working voltages from 3.3 kV up to and including 11 kV | 0 | Nov, 2021 | Download | |
| 67 |
IS 11979 : 1987 Reviewed In : 2017 |
Dimensions for moulds for cast resin based straight through joints for cables for working voltages from 3.3 kV up to and including 11 kV | 0 | Download | ||
| 68 |
IS 1255 : 1983 Reviewed In : 2016 (Second Revision) |
Code of practice for installation and maintenance of power cables up to and including 33 kV rating (Second Revision) | 1 | Nov, 2016 | Download | |
| 69 |
IS 12909 : 1990 Reviewed In : 2020 |
Power cables - Dimensions for moulds for cast resin based outdoor terminations for voltages above 1 100 volts and up to and including 1 1000 volts | 0 | Mar, 2020 | Download | |
| 70 |
IS 12943 : 1990 Reviewed In : 2020 |
Brass glands for PVC cables - Specification | 0 | Mar, 2020 | Download | |
| 71 |
IS 13573 (Part 1) : 2011 Reviewed In : 2024 (First Revision) |
Cable accessories for extruded power cables - Specification: Part 1 for working voltages from 1.1 kV up to and including 3.3 kV (E) - Test methods and test requirements (First Revision) | 0 | Sep, 2024 | Buy | |
| 72 |
IS 13573 (Part 2) : 2011 Reviewed In : 2021 (First Revision) |
Cable accessories for extruded power cables - Specification: Part 2 for working voltages from 3.3 kV (Ue) up to and including 33 kV (E) - Test requirements (First Revision) | 0 | Nov, 2021 | Buy | |
| 73 |
IS 13573 (Part 3) : 2011 Reviewed In : 2024 (First Revision) |
Cable accessories for extruded power cables - Specification: Part 3 for working voltages from 3.3 kV (UE) up to and including 33 KV (E) - Test methods (First Revision) | 0 | May, 2024 | Buy | |
| 74 |
IS 13705 : 1993 Reviewed In : 2024 Reaffirmed but not taken up for revision |
Transition joints of cables for working voltages from 11 kV up to and including 33 kV - Performance requirements and type tests | 0 | May, 2024 | Download | |
| 75 |
IS 14255 : 1995 Reviewed In : 2020 |
Aerial bunched cables - For working voltages up to and including 1 100 Volts - Specification | 1 | Mar, 2020 | Download | |
| 76 |
IS 14494 : 2019 Reviewed In : 2024 (First Revision) |
Elastomer insulated flexible cables for use in mines - Specification (First Revision) | 0 | May, 2024 | Download | |
| 77 |
IS 1554 (Part 1) : 1988 Reviewed In : 2020 (Third Revision) |
Specification for PVC insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1 100 V (Third Revision) | 5 | Feb, 2020 | Buy | |
| 78 |
IS 1554 (Part 2) : 1988 Reviewed In : 2020 (Second Revision) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) | 4 | Mar, 2020 | Buy | |
| 79 |
IS 16246 : 2015 Reviewed In : 2020 |
Elastomer insulated cables with limited circuit integrity when affected by fire - Specification | 1 | Nov, 2020 | Buy | |
| 80 |
IS 16269 : 2018 Reviewed In : 2024 |
Recommended Short Circuit Ratings of Electric Cables with Rated Voltage from 1.1 kV to 220 kV - Specification | 0 | May, 2024 | Download | |
| 81 |
IS 17048 : 2018 Reviewed In : 2024 |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification | 1 | May, 2024 | Buy | |
| 82 |
IS 17293 : 2020 |
Electric Cables for Photovoltaic Systems for Rated Voltage 1 500 V d.c. | 0 | ---- | Download | |
| 83 |
IS 17505 (Part 1) : 2021 IEC 60721-2-7: 2018 IEC 60721-2-7: 2018 |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1 100 V a.c. and 1 500 V d.c. | 1 | ---- | Buy | |
| 84 |
IS 18833 : 2024 |
High Voltage Direct Current (HVDC) Power Transmission - Cables with Extruded Insulation and Their Accessories for Rated Voltages Up to 320 kV for Land Applications - Test Methods and Requirements | 0 | ---- | Buy | |
| 85 |
IS 2465 : 1984 Reviewed In : 2021 (Second Revision) |
Specification for cables for motor vehicles (Second Revision) | 1 | Nov, 2021 | Download | |
| 86 |
IS 2593 : 2023 (Second Revision) |
Flexible Cables for Miners' Cap Lamps - Specification (Second Revision) | 0 | ---- | Buy | |
| 87 |
IS 3961 : 2016 |
Recommended Current Ratings for Cables Part 6 Crosslinked Polyethylene Insulated PVC Sheathed Cables | 0 | ---- | Download | |
| 88 |
IS 3961 (Part 2) : 2017 Reviewed In : 2024 (First Revision) |
Recommended current ratings for cables: Part 2 PVC insulated and PVC sheathed heavy duty cables (First Revision) | 0 | Apr, 2024 | Download | |
| 89 |
IS 3961 (Part 3) : 1968 Reviewed In : 2021 |
Recommended current ratings for cables: Part 3 rubber insulated cables | 1 | Nov, 2021 | Buy | |
| 90 |
IS 3961 (Part 5) : 1968 Reviewed In : 2021 |
Recommended current ratings for cables: Part 5 pvc insulated light duty cables | 0 | Nov, 2021 | Download | |
| 91 |
IS 3961 (Part 6) : 2016 Reviewed In : 2024 |
Recommended Current Ratings for Cables Part 6 Crosslinked Polyethylene Insulated PVC Sheathed Cables | 0 | May, 2024 | Download | |
| 92 |
IS 3961 (Part 7) : 2017 Reviewed In : 2024 |
Recommended current ratings for cables: Part 7 crosslinked polyethylene insulated thermoplastic sheathed cables | 0 | Apr, 2024 | Download | |
| 93 |
IS 4289 (Part 1) : 1984 Reviewed In : 2021 (First Revision) |
Specification for flexible cables for lifts and other flexible connections: Part 1 elastomer insulated cables (First Revision) | 0 | Nov, 2021 | Buy | |
| 94 |
IS 4289 (Part 2) : 2000 Reviewed In : 2020 |
Flexible cables for lifts and other flexible connections - Specification: Part 2 pvc insulated circular cables | 0 | Mar, 2020 | Buy | |
| 95 |
IS 5819 : 2024 (First Revision) |
Recommended short-circuit ratings of high voltage PVC cables (First Revision) | 0 | ---- | Buy | |
| 96 |
IS 5831 : 1984 Reviewed In : 2021 (First Revision) |
Specification for PVC insulation and sheath of electric cables (First Revision) | 2 | Nov, 2021 | Buy | |
| 97 |
IS 5950 : 2024 (Second Revision) |
Shot Firing Cables (for Use Other than in Shafts) - Specification (Second Revision) | 0 | ---- | Buy | |
| 98 |
IS 6380 : 2024 (Second Revision) |
Elastomeric Insulation and Sheath of Electric Cables - Specification (Second Revision) | 0 | ---- | Buy | |
| 99 |
IS 694 : 2010 Reviewed In : 2020 (Fourth Revision) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 1 100 V (Fourth Revision) | 4 | Mar, 2020 | Buy | |
| 100 |
IS 7093 : 1973 |
Specification for straight through joint boxes and lead sleeves for paper insulated lead sheathed cables up to and including 11 kV | 0 | ---- | Download | |
| 101 |
IS 7098 (Part 1) : 2025 (Second Revision) |
Crosslinked Polyethylene Insulated Thermoplastic Sheathed Cables - Specification Part 1 For Working Voltages up to and Including 1 100 Volts (Second Revision) | 0 | ---- | Buy | |
| 102 |
IS 7098 (Part 1) : 1988 Reviewed In : 2020 (First Revision) |
Specification for crosslinked polyethylene insulated PVC sheathed cables: Part 1 for working voltages up to and including 1 100 volts (First Revision) | 5 | Mar, 2020 | Download | |
| 103 |
IS 7098 (Part 2) : 2011 Reviewed In : 2021 (Second Revision) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) | 2 | Nov, 2021 | Buy | |
| 104 |
IS 7098 (Part 3) : 1993 Reviewed In : 2025 |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV | 4 | Jan, 2025 | Download | |
| 105 |
IS 8130 : 2013 Reviewed In : 2024 (Second Revision) |
Conductors for insulated electric cables and flexible cords - Specification (Second Revision) | 2 | Aug, 2024 | Buy | |
| 106 |
IS 8308 : 1993 Reviewed In : 2019 (First Revision) |
Compression type tubular in - Line connectors for aluminium conductors of insulated cables - Specification (First Revision) | 0 | Download | ||
| 107 |
IS 8309 : 1993 Reviewed In : 2019 (First Revision) |
Compression type tubular terminal ends for aluminium conductors of insulated cables - Specification (First Revision) | 1 | Download | ||
| 108 |
IS 8337 : 1976 Reviewed In : 2020 |
Specification for performance requirements of compression joints of aluminium conductors in insulated cables | 1 | Mar, 2020 | Buy | |
| 109 |
IS 8394 : 1977 Reviewed In : 2017 |
Specification for soldering and welding type terminal ends for conductors of insulated cables | 2 | Download | ||
| 110 |
IS 8438 : 1987 Reviewed In : 2017 (First Revision) |
Specification for moulds for cast resin based straight through joints for cables for voltages up to and including 1 100 volts (First Revision) | 0 | Download | ||
| 111 |
IS 9553 : 1987 Reviewed In : 2017 (First Revision) |
Specification for moulds suitable for cast resin based terminations for cables for voltages up to and including 1 100 V (First Revision) | 0 | Download | ||
| 112 |
IS 9646 : 1992 Reviewed In : 2019 (First Revision) |
Moulds suitable for cast resin - Based joints for cables for voltages upto and including 1 100 V - Specification (First Revision) | 0 | Apr, 2019 | Download | |
| 113 |
IS 9857 : 1990 Reviewed In : 2020 (First Revision) |
Welding cables - Specification (First Revision) | 1 | Mar, 2020 | Buy | |
| 114 |
IS 9968 (Part 1) : 1988 Reviewed In : 2020 (First Revision) |
Specification for elastomer insulated cables: Part 1 for working voltages up to and including 1 100 volts (First Revision) | 3 | Mar, 2020 | Download | |
| 115 |
IS 9968 (Part 1) : 2025 (Second Revision) |
Elastomer Insulated Cables - Specification Part 1 for Working Voltages up to and including 1100 volts (Second Revision) | 0 | ---- | Buy | |
| 116 |
IS 9968 (Part 2) : 2002 Reviewed In : 2024 (First Revision) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) | 2 | Aug, 2024 | Download |